Two New ES3000 Locomotives Headed to Ukraine

Ukrainian Railways (Ukrzaliznytsia) will add two ES3000 battery shunting locomotives produced by Bulgarian firm Express Service OOD, scheduled for delivery in December 2026. These battery-electric locomotives join an existing procurement program that will expand the operator’s non-diesel shunting capability at stations, freight terminals, and maintenance yards.

Battery fleet growth and delivery schedule

Express Service OOD delivered two ES3000 units on 15 June 2026, bringing the operator’s fleet to six. The two additional ES3000 locomotives arriving in December 2026 will increase the fleet to eight, and the overall procurement plan foresees ten units, with the final pair expected in the first quarter of 2027. This staged delivery allows Ukrzaliznytsia to deploy, monitor, and refine operational practices between shipments.

Technical profile: weight, power, speed, and battery metrics

The ES3000 weighs 48 tonnes and provides up to 3,000 tonnes of shunting capacity under typical yard conditions. Its traction system delivers a nominal 90 kW and a maximum service speed of 10 km/h, optimized for low-speed maneuvers. The traction battery capacity is 220 kWh; a full charge can take up to 5.5 hours depending on the charger and grid conditions. Manufacturer data indicates battery life exceeding 1,800 full cycles, which supports multi-year yard duty when managed with partial-charge strategies opportunity and charging during shifts.

Operational benefits and typical use cases

Battery shunters replace diesel units for yard movement tasks that involve frequent stopping, low speeds, and predictable duty cycles. Specific benefits include:

Lower local emissions: eliminating exhaust in populated station areas and enclosed maintenance sheds.

Reduced operating noise: quieter operations improve worker conditions and enable extended-hour activity near urban zones.

Energy cost control: electricity can be cheaper and more stable than diesel, particularly when paired with off-peak charging schedules or on-site renewable generation.

Typical deployments: assembling freight consists of, transferring wagons between terminals, light transfer moves between adjacent yards, and maintenance shunting where diesel fumes would disrupt inspections or worker health.

How operators integrate battery shunters step‑by‑step

1. Fleet assessment: analyze yard tasks, axle loads, and duty cycles to match ES3000 capabilities to routes.

2. Charging infrastructure planning: specify charger power, cable management, and siting to support 5.5-hour full charges opportunity or charging patterns.

3. Crew training: teach battery management, regenerative braking use, and emergency procedures for high-voltage equipment.

4. Maintenance planning: introduce battery health monitoring, scheduled capacity tests, and thermal management inspections to preserve the 1,800+ cycle life.

5. Trial deployment: run pilot shifts to refine scheduling, measure energy consumption per shift, and verify expected reductions in diesel use and emissions.

Performance metrics and examples for yard planners

Use these example calculations to estimate energy needs and utilization:

Example 1 — Single-shift yard duty: a locomotive working an 8-hour shift with an average draw of 20 kW requires ~160 kWh. A 220 kWh battery accommodates one full 8-hour shift with reserve margin for regenerative gains.

Example 2 — Two-shift rotation with opportunity charging: two locomotives can alternate with a midday 2–3 hour opportunity charge; average draw per shift drops to ~100–130 kWh, reducing deep cycles and extending battery life.

Expected lifecycle costs and savings factors

Battery shunters shift cost structure from fuel and mechanical maintenance to energy and battery lifecycle management. Key cost drivers and savings:

Saved diesel fuel costs: measurable by comparing liters consumed per shunting hour before/after electrification.

Lower mechanical wear: electric traction reduces engine maintenance and oil changes.

Battery replacement: plan for mid-life battery refurbishment or modules replacement after significant cycle degradation, typically modeled across a 7–10 year window depending on duty profile.

Environmental and regulatory impact

Replacing diesel shunters reduces local NOx, PM, and CO2 emissions at emission-sensitive sites. Where grid electricity has a low-carbon mix, lifecycle CO2 savings increase substantially. Operators can quantify emissions reductions by multiplying shifted diesel liters by standard emission factors or by metering kWh consumed and applying national grid emission intensities.

What to monitor after introducing ES3000 units

Track these KPIs to validate benefits and guide scale-up:

Energy consumption per shift (kWh) — baseline vs. post-deployment.

Diesel displacement (liters) — direct fuel savings attributed to battery units.

Battery state of health (SoH) — capacity retention over time and per-cycle degradation.

Availability and reliability — percentage of scheduled time the locomotive is operational without failure.

Regularly reviewing these metrics lets planners adjust charging strategy, schedule preventive maintenance, and plan procurement of additional units.